Page 14 Inclinometer RS232 Current Datasheet Version: 20130503
INCLINOMETER
RS232 CURRENT
<Code transmission rate>
<Code transmission rate>
Strings per second, 1 string contains x and y-value
“0“
reserved
“1“
25 Strings/s
1)
“2“
10 Strings/s, Default value
2)
“3“
5 Strings/s
“4“
2 Strings/s
“5“
1 Strings/s
“6“
0,2 Strings/s
“7“
0,1 Strings/s
“8“, “9”
not defined
1) only allowed with baud rate of at least 9600 Bd
2) only allowed with baud rate of at least 4800 Bd
<Code Baud Rate>
<Code Baud Rate>
Baud rate
“0“
2400 Baud
“1“
4800 Baud
“2“
9600 Baud, Default value
“3“
19200 Baud
“4“
38400 Baud
“5“
57600 Baud
“6“, “7“, ”8“, ”9“
not defined